Examples of applying a QC mask to a sample group with one common QC mask

Example: Cross-rack with propagation

Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13

Rack size is N/A

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

Cross-rack

DUPLICATE

DUP

O

UNK ONLY

10

5

IMMEDIATELY AFTER

1

 

Y

 

 

 

U1 U2 DU2 U3 U4 DU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13

Cross-rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 U2 LB DU2 U3 U4 DU4 DU4 U5 DU5 U6 U7 LB U8 U9 DU9 U10 U11 U12 U13

Output Rack 1) U1 U2 LB DU2 U3 U4 DU4 DU4 U5 DU5 U6 U7 LB U8 U9 DU9 U10 U11 U12 U13

Example: In-rack Blank

Input Sample Group is U1

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

0

 

10

1

 

1

 

Y

N

LB

 

LB U1

Output Rack 1) LB U1

Example: In-rack Blank with more input Samples

Input Sample Group is U1 U2 U3 U4 U5 DU5 U6 U7 U8 U9 U10

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

0

 

10

1

 

1

 

Y

N

LB

 

U1 U2 U3 U4 LB U5 DU5 U6 U7 U8 U9 LB U10

Output Rack 1) U1 U2 U3 U4 LB U5 DU5 U6 U7 U8 U9 LB U10

Example: In-rack Blank with input Samples forcing another Rack

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

0

 

10

1

 

1

 

Y

N

LB

 

U1 U2 U3 U4 U5 LB U6 U7 U8 U9 U10 U11 U12 LB U13 U14 U15 U16 U17 U18;

LB U19

Output Rack 1) U1 U2 U3 U4 U5 LB U6 U7 U8 U9 U10 U11 U12 LB U13 U14 U15 U16 U17 U18

Output Rack 2) LB U19

Example: In-rack Blank with Duplicate QC Samples in the input

Input Sample Group is U1 DU1 U2 U3 U4 U5 U6 DU6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 DU15 U16 U17 U18 U19

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

0

 

10

1

 

1

 

Y

N

LB

 

U1 DU1 U2 U3 LB U4 U5 U6 DU6 U7 U8 LB U9 U10 U11 DU11 U12 U13 U14 U15;

DU15 LB U16 U17 U18 U19

Output Rack 1) U1 DU1 U2 U3 LB U4 U5 U6 DU6 U7 U8 LB U9 U10 U11 DU11 U12 U13 U14 U15

Output Rack 2) DU15 LB U16 U17 U18 U19

Example: In-rack Blank with a different Rack size

Input Sample Group is U1 DU1 U2 U3 U4 U5 U6 DU6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 DU15 U16 U17 U18 U19

Rack size is 25

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

0

 

10

1

 

1

 

Y

N

LB

 

U1 DU1 U2 U3 LB U4 U5 U6 DU6 U7 U8 LB U9 U10 U11 DU11 U12 U13 U14 U15 DU15 LB U16 U17 U18;

U19 LB

Output Rack 1) U1 DU1 U2 U3 LB U4 U5 U6 DU6 U7 U8 LB U9 U10 U11 DU11 U12 U13 U14 U15 DU15 LB U16 U17 U18

Output Rack 2) U19 LB

Example: In-rack Blank with fixed selection where empty Rack slots after the last Sample are squeezed out

Input Sample Group is U1

Rack size 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 LB

Output Rack 1) U1 LB

Example: In-rack Blank with fixed selection where there are no empty Rack slots after the last Sample

Input Sample Group is U1 U2

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 U2 LB

Output Rack 1) U1 U2 LB

Example: In-rack Blank with fixed selection and more input Samples

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 U2 LB U3 U4 U5 U6 U7 U8 U9 U10

Output Rack 1) U1 U2 LB U3 U4 U5 U6 U7 U8 U9 U10

Example: In-rack Blank with fixed selection and input Samples forcing another Block selection

Input Sample Group is U1 U2 U3 U4 U5 DU5 U6 U7 U8 U9 U10 U11

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 U2 LB U3 U4 U5 DU5 U6 U7 U8 U9 U10 LB U11

Output Rack 1) U1 U2 LB U3 U4 U5 DU5 U6 U7 U8 U9 U10 LB U11

Example: In-rack Blank with fixed selection and input Samples forcing other Rack and empty Rack slots after the last Sample are squeezed out

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 U2 LB U3 U4 U5 U6 U7 U8 U9;

U10 U11 LB U12 U13 U14 U15 U16 U17 U18;

U19 LB

Output Rack 1) U1 U2 LB U3 U4 U5 U6 U7 U8 U9 U10 U11 LB U12 U13 U14 U15 U16 U17 U18

Output Rack 3) U19 LB

Example: In-rack Blank with Duplicate QC Samples in the input and fixed selection

Input Sample Group is U1 DU1 U2 U3 U4 U5 U6 DU6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 DU15 U16 U17 U18 U19

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 DU1 LB U2 U3 U4 U5 U6 DU6 U7 U8 U9 LB U10 U11 DU11 U12 U13 U14 U15;

DU15 U16 LB U17 U18 U19

Output Rack 1) U1 DU1 LB U2 U3 U4 U5 U6 DU6 U7 U8 U9 LB U10 U11 DU11 U12 U13 U14 U15

Output Rack 2) DU15 U16 LB U17 U18 U19

Example: In-rack Blank with different Block size

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

0

 

5

1

 

1

 

Y

N

LB

 

U1 U2 U3 LB U4 LB U5 U6 U7 U8 U9 U10 U11 LB U12 U13 U14 U15 U16 LB;

U17 U18 U19 U20 LB

Output Rack 1) U1 U2 U3 LB U4 LB U5 U6 U7 U8 U9 U10 U11 LB U12 U13 U14 U15 U16 LB U17

Output Rack 2) U18 U19 U20 LB

Example: In-rack Standard with different Block size

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

STANDARD

STD

0

 

5

1

 

1

 

Y

Y

 

STD_GP

U1 U2 U3 U4 STD1 U4 U5 U6 STD2 U7 U8 U9 U10 U11 STD3 U12 U13 U14 U15 U16 STD1;

U17 U18 U19 U20 STD2

Output Rack 1) U1 U2 U3 U4 STD1 U4 U5 U6 STD2 U7 U8 U9 U10 U11 STD3 U12 U13 U14 U15 U16 STD1

Output Rack 2) U17 U18 U19 U20 STD2

Example: In-rack Duplicate

Input Sample Group is U1

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

DUPLICATE

DUP

0

UNK ONLY

10

1

IMMEDIATELY AFTER

1

 

Y

N

LB

 

U1 DU1

Output Rack 1) U1 DU1

Example: In-rack Duplicate with more input Samples

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

DUPLICATE

DUP

0

UNK ONLY

10

1

IMMEDIATELY AFTER

1

 

Y

N

LB

 

U1 U2 U3 U4 U5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 DU16 U17 U18;

U19 D19 U20

Output Rack 1) U1 U2 U3 U4 U5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 DU16 U17 U18

Output Rack 2) U19 D19 U20

Example: In-rack Duplicate with different Block size

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

DUPLICATE

DUP

0

UNK ONLY

4

1

IMMEDIATELY AFTER

1

 

Y

N

LB

 

U1 U2 U3 U4 DU4 U5 U6 U7 DU7 U8 U9 DU9 U10 U11 U12 U13 DU13 U14 U15 U16;

U17 D17 U18 U19 U20

Output Rack 1) U1 U2 U3 U4 DU4 U5 U6 U7 DU7 U8 U9 DU9 U10 U11 U12 U13 DU13 U14 U15 U16

Output Rack 2) U17 D17 U18 U19 U20

Example: In-rack Duplicate with different Minimum—the first block in the second Rack for Duplicate placement does not contain the Minimum so no Duplicate is placed

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

DUPLICATE

DUP

0

UNK ONLY

10

5

IMMEDIATELY AFTER

1

 

Y

N

LB

 

U1 U2 U3 U4 DU4 U5 U6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 U16 U17 U18;

U19 U20

Output Rack 1) U1 U2 U3 U4 DU4 U5 U6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 U16 U17 U18

Output Rack 2) U19 U20

Example: In-rack Duplicate with different Placement—Rack 1 has two groups of Unknowns for Duplicate placement: first Group U1..U10, second Group U11..U15. A Duplicate is created for the first Group. A Duplicate cannot be created for the second Group because although the Minimum is met, no room exists in the Rack for it, so it cannot be created

Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 U17 D17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

DUPLICATE

DUP

0

UNK ONLY

10

5

END

1

 

Y

N

LB

 

U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU8U15;

U16 U17 D17 U18 U19 U20 DU19

Output Rack 1) U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU8U15

Output Rack 2) U16 U17 D17 U18 U19 U20 DU19

Example: In-rack Replicate with different Placement

Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 U17 D17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

REPLICATE

REP

0

UNK AND DUP

10

5

END

1

 

Y

N

LB

 

U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 RDU2 RU11;

U15 U16 U17 D17 U18 U19 U20 DU19

Output Rack 1) U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 RDU2 RU11

Output Rack 2) U15 U16 U17 D17 U18 U19 U20 DU19

Example: In-rack Replicate with fixed Selection, but Sample does not exist at nominated place

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

REPLICATE

REP

3

UNK AND DUP

10

1

IMMEDIATELY AFTER

1

 

Y

N

LB

 

U1 U2 U3 RU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 RU13 U14 U15 U16 U17 U18;

U19 U20

Output Rack 1) U1 U2 U3 RU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 RU13 U14 U15 U16 U17 U18

Output Rack 2) U19 U20

Example: In-rack Replicate with fixed Selection

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

REPLICATE

REP

3

UNK AND DUP

10

1

IMMEDIATELY AFTER

1

 

Y

N

LB

 

U1 U2 U3 RU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 RU13 U14 U15 U16 U17 U18;

U19 U20 U21 R21

Output Rack 1) U1 U2 U3 RU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 RU13 U14 U15 U16 U17 U18

Output Rack 2) U19 U20 U21 R21

Example: In-rack Replicate with limited Selection Type—Rack 1 has two Groups of Unknowns for Replicate placement: first Group U1..U10, second Group U11..U15. A Replicate is created for the first Group. A Replicate cannot be created for the second Group because although the Minimum is met, no room exists in the Rack for it, so it cannot be created

Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 U17 D17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

REPLICATE

REP

0

UNK ONLY

10

5

END

1

 

Y

N

LB

 

U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 RU3;

U16 U17 D17 U18 U19 U20 RU19

Output Rack 1) U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 RU3

Output Rack 2) U16 U17 D17 U18 U19 U20 RU19

Example: In-rack Replicate with different Minimum

Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14 U15 U16 U17 D17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

REPLICATE

REP

0

UNK ONLY

10

5

IMMEDIATELY AFTER

1

 

Y

N

LB

 

U1 U2 DU2 U3 U4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14;

U15 U16 RU16 U17 D17 U18 U19 U20

Output Rack 1) U1 U2 DU2 U3 U4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14

Output Rack 2) U15 U16 RU16 U17 D17 U18 U19 U20

Example: In-rack Replicate with different Number to Apply

Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14 U15 U16 U17 D17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

REPLICATE

REP

0

UNK ONLY

10

1

END

2

 

Y

N

LB

 

U1 U2 DU2 U3 U4 RU4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 RU12 RU12;

U13 U14 DU14 U15 U16 RU16 RU16 U17 D17 U18 U19 U20

Output Rack 1) U1 U2 DU2 U3 U4 RU4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 RU12 RU12

Output Rack 2) U13 U14 DU14 U15 U16 RU16 RU16 U17 D17 U18 U19 U20

Example: In-rack Replicate with different Number to Apply and Minimum

Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14 U15 U16 U17 D17 U18 U19 U20

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

REPLICATE

REP

0

UNK ONLY

10

5

END

2

 

Y

N

LB

 

U1 U2 DU2 U3 U4 RU4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14;

DU14 U15 U16 RU16 RU16 U17 D17 U18 U19 U20

Output Rack 1) U1 U2 DU2 U3 U4 RU4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14

Output Rack 2) DU14 U15 U16 RU16 RU16 U17 D17 U18 U19 U20

Example: In-rack Spike with different Selection Type

Input Sample Group is U1 DU1 U2 U3 U4 U5 U6 DU6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 DU15 U16 U17 U18 U19 U20 U21 U22 U23 U24 U25

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

SPIKE

SPK

0

UNK AND DUP

10

1

IMMEDIATELY AFTER

1

 

Y

N

LB

 

U1 DU1 U2 U3 SU3 U4 U5 U6 DU6 U7 U8 U9 SU9 U10 U11 DU11 U12 U13 U14 U15;

DU15 U16 U17 U18 SU18 U19 U20 U21 U22 U23 U24 U25 SU18

Output Rack 1) U1 DU1 U2 U3 SU3 U4 U5 U6 DU6 U7 U8 U9 SU9 U10 U11 DU11 U12 U13 U14 U15

Output Rack 2) DU15 U16 U17 U18 SU18 U19 U20 U21 U22 U23 U24 U25 SU18

Example: In-rack Replicate and In-rack Blank

Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

REPLICATE

REP

0

UNK AND DUP

10

5

IMMEDIATELY AFTER

1

 

Y

 

 

 

U1 U2 DU2 U3 U4 RU4 DU4 U5 DU5 RDU5 U6 U7 U8 RU8 U9 DU9 U10 U11 U12 U13

In=rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 U2 LB DU2 U3 U4 RU4 DU4 U5 DU5 RDU5 U6 LB U7 U8 RU8 U9 DU9 U10 U11;

U12 U13 LB

Output Rack 1) U1 U2 BLK DU2 U3 U4 RU4 DU4 U5 DU5 RDU5 U6 BLK U7 U8 RU8 U9 DU9 U10 U11

Output Rack 2) U12 U13 BLK

Example: Cross-rack Duplicate and In-rack Blank

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20

Rack size t

20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

Cross-rack

DUPLICATE

DUP

0

UNK ONLY

10

5

IMMEDIATELY AFTER

1

 

Y

 

 

 

U1 U2 U3 U4 U5 DU5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 DU18 U19 U20

In-rack

BLANK

BLK

3

 

10

1

 

1

 

Y

N

LB

 

U1 U2 LB U3 U4 U5 DU5 U6 U7 U8 U9 U10 LB U11 U12 U13 U14 U15 U16 U17;

U18 DU18 LB U19 U20

Output Rack 1) U1 U2 LB U3 U4 U5 DU5 U6 U7 U8 U9 U10 LB U11 U12 U13 U14 U15 U16 U17

Output Rack 2) U18 DU18 LB U19 U20

Example: Cross-rack Duplicate and In-rack Blank with different Selection and Block size

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21 U22 U23 U24

Rack size is 20

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

Cross-rack

DUPLICATE

DUP

0

UNK ONLY

10

5

IMMEDIATELY AFTER

1

 

Y

 

 

 

U1 U2 U3 DU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 DU15 U16 U17 U18 U19 U20 U21 DU21 U22 U23 U24

In-rack

BLANK

BLK

19

 

20

1

 

2

 

Y

N

LB

 

U1 U2 U3 DU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 DU15 U16 LB LB;

U17 U18 U19 U20 U21 DU21 U22 U23 U24 LB LB

Output Rack 1) U1 U2 U3 DU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 DU15 U16 LB LB

Output Rack 2) U17 U18 U19 U20 U21 DU21 U22 U23 U24 LB LB

Example: In-rack Blank and In-rack Replicate—The Replicate placement is processed first

Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21 U22 U23 U24

Rack size is 10

Stream Type

Analytical Type

QC Type Code

Selection

Selection Type

Per Block

Minimum

Placement

Number to Apply

Secondary QC Type Code

Propagate

Use Group

Standard Code

Standard Group Code

output Sample Stream

In-rack

BLANK

BLK

10

 

10

1

 

1

 

Y

N

LB

 

U1 U2 U3 U4 U5 U6 RU6 U7 U8 LB U9 U10 U11 RU11 U12 U13 U14 U15 U16 LB;

U17 U18 U19 U20 U21 U22 U23 U24 LB

In-rack

REPLICATE

REP

0

UNK ONLY

10

5

IMMEDIATELY AFTER

1

 

Y

 

 

 

U1 U2 U3 U4 U5 U6 RU6 U7 U8 U9 U10 U11 RU11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21 U22 U23 U24

Output Rack 1) U1 U2 U3 U4 U5 U6 RU6 U7 U8 LB U9 U10 U11 RU11 U12 U13 U14 U15 U16 LB

Output Rack 2) U17 U18 U19 U20 U21 U22 U23 U24 LB