Examples of applying a QC mask to a sample group with one common QC mask
Example: Cross-rack with propagation
Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13
Rack size is N/A
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Cross-rack |
DUPLICATE |
DUP |
O |
UNK ONLY |
10 |
5 |
IMMEDIATELY AFTER |
1 |
|
Y |
|
|
|
U1 U2 DU2 U3 U4 DU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 |
|
Cross-rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 LB DU2 U3 U4 DU4 DU4 U5 DU5 U6 U7 LB U8 U9 DU9 U10 U11 U12 U13 |
Output Rack 1) U1 U2 LB DU2 U3 U4 DU4 DU4 U5 DU5 U6 U7 LB U8 U9 DU9 U10 U11 U12 U13
Example: In-rack Blank
Input Sample Group is U1
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
0 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
LB U1 |
Output Rack 1) LB U1
Example: In-rack Blank with more input Samples
Input Sample Group is U1 U2 U3 U4 U5 DU5 U6 U7 U8 U9 U10
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
0 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 U3 U4 LB U5 DU5 U6 U7 U8 U9 LB U10 |
Output Rack 1) U1 U2 U3 U4 LB U5 DU5 U6 U7 U8 U9 LB U10
Example: In-rack Blank with input Samples forcing another Rack
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
0 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 U3 U4 U5 LB U6 U7 U8 U9 U10 U11 U12 LB U13 U14 U15 U16 U17 U18; LB U19 |
Output Rack 1) U1 U2 U3 U4 U5 LB U6 U7 U8 U9 U10 U11 U12 LB U13 U14 U15 U16 U17 U18
Output Rack 2) LB U19
Example: In-rack Blank with Duplicate QC Samples in the input
Input Sample Group is U1 DU1 U2 U3 U4 U5 U6 DU6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 DU15 U16 U17 U18 U19
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
0 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 DU1 U2 U3 LB U4 U5 U6 DU6 U7 U8 LB U9 U10 U11 DU11 U12 U13 U14 U15; DU15 LB U16 U17 U18 U19 |
Output Rack 1) U1 DU1 U2 U3 LB U4 U5 U6 DU6 U7 U8 LB U9 U10 U11 DU11 U12 U13 U14 U15
Output Rack 2) DU15 LB U16 U17 U18 U19
Example: In-rack Blank with a different Rack size
Input Sample Group is U1 DU1 U2 U3 U4 U5 U6 DU6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 DU15 U16 U17 U18 U19
Rack size is 25
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
0 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 DU1 U2 U3 LB U4 U5 U6 DU6 U7 U8 LB U9 U10 U11 DU11 U12 U13 U14 U15 DU15 LB U16 U17 U18; U19 LB |
Output Rack 1) U1 DU1 U2 U3 LB U4 U5 U6 DU6 U7 U8 LB U9 U10 U11 DU11 U12 U13 U14 U15 DU15 LB U16 U17 U18
Output Rack 2) U19 LB
Example: In-rack Blank with fixed selection where empty Rack slots after the last Sample are squeezed out
Input Sample Group is U1
Rack size 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 LB |
Output Rack 1) U1 LB
Example: In-rack Blank with fixed selection where there are no empty Rack slots after the last Sample
Input Sample Group is U1 U2
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 LB |
Output Rack 1) U1 U2 LB
Example: In-rack Blank with fixed selection and more input Samples
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 LB U3 U4 U5 U6 U7 U8 U9 U10 |
Output Rack 1) U1 U2 LB U3 U4 U5 U6 U7 U8 U9 U10
Example: In-rack Blank with fixed selection and input Samples forcing another Block selection
Input Sample Group is U1 U2 U3 U4 U5 DU5 U6 U7 U8 U9 U10 U11
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 LB U3 U4 U5 DU5 U6 U7 U8 U9 U10 LB U11 |
Output Rack 1) U1 U2 LB U3 U4 U5 DU5 U6 U7 U8 U9 U10 LB U11
Example: In-rack Blank with fixed selection and input Samples forcing other Rack and empty Rack slots after the last Sample are squeezed out
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 LB U3 U4 U5 U6 U7 U8 U9; U10 U11 LB U12 U13 U14 U15 U16 U17 U18; U19 LB |
Output Rack 1) U1 U2 LB U3 U4 U5 U6 U7 U8 U9 U10 U11 LB U12 U13 U14 U15 U16 U17 U18
Output Rack 3) U19 LB
Example: In-rack Blank with Duplicate QC Samples in the input and fixed selection
Input Sample Group is U1 DU1 U2 U3 U4 U5 U6 DU6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 DU15 U16 U17 U18 U19
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 DU1 LB U2 U3 U4 U5 U6 DU6 U7 U8 U9 LB U10 U11 DU11 U12 U13 U14 U15; DU15 U16 LB U17 U18 U19 |
Output Rack 1) U1 DU1 LB U2 U3 U4 U5 U6 DU6 U7 U8 U9 LB U10 U11 DU11 U12 U13 U14 U15
Output Rack 2) DU15 U16 LB U17 U18 U19
Example: In-rack Blank with different Block size
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
0 |
|
5 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 U3 LB U4 LB U5 U6 U7 U8 U9 U10 U11 LB U12 U13 U14 U15 U16 LB; U17 U18 U19 U20 LB |
Output Rack 1) U1 U2 U3 LB U4 LB U5 U6 U7 U8 U9 U10 U11 LB U12 U13 U14 U15 U16 LB U17
Output Rack 2) U18 U19 U20 LB
Example: In-rack Standard with different Block size
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
STANDARD |
STD |
0 |
|
5 |
1 |
|
1 |
|
Y |
Y |
|
STD_GP |
U1 U2 U3 U4 STD1 U4 U5 U6 STD2 U7 U8 U9 U10 U11 STD3 U12 U13 U14 U15 U16 STD1; U17 U18 U19 U20 STD2 |
Output Rack 1) U1 U2 U3 U4 STD1 U4 U5 U6 STD2 U7 U8 U9 U10 U11 STD3 U12 U13 U14 U15 U16 STD1
Output Rack 2) U17 U18 U19 U20 STD2
Example: In-rack Duplicate
Input Sample Group is U1
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
DUPLICATE |
DUP |
0 |
UNK ONLY |
10 |
1 |
IMMEDIATELY AFTER |
1 |
|
Y |
N |
LB |
|
U1 DU1 |
Output Rack 1) U1 DU1
Example: In-rack Duplicate with more input Samples
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
DUPLICATE |
DUP |
0 |
UNK ONLY |
10 |
1 |
IMMEDIATELY AFTER |
1 |
|
Y |
N |
LB |
|
U1 U2 U3 U4 U5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 DU16 U17 U18; U19 D19 U20 |
Output Rack 1) U1 U2 U3 U4 U5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 DU16 U17 U18
Output Rack 2) U19 D19 U20
Example: In-rack Duplicate with different Block size
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
DUPLICATE |
DUP |
0 |
UNK ONLY |
4 |
1 |
IMMEDIATELY AFTER |
1 |
|
Y |
N |
LB |
|
U1 U2 U3 U4 DU4 U5 U6 U7 DU7 U8 U9 DU9 U10 U11 U12 U13 DU13 U14 U15 U16; U17 D17 U18 U19 U20 |
Output Rack 1) U1 U2 U3 U4 DU4 U5 U6 U7 DU7 U8 U9 DU9 U10 U11 U12 U13 DU13 U14 U15 U16
Output Rack 2) U17 D17 U18 U19 U20
Example: In-rack Duplicate with different Minimum—the first block in the second Rack for Duplicate placement does not contain the Minimum so no Duplicate is placed
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
DUPLICATE |
DUP |
0 |
UNK ONLY |
10 |
5 |
IMMEDIATELY AFTER |
1 |
|
Y |
N |
LB |
|
U1 U2 U3 U4 DU4 U5 U6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 U16 U17 U18; U19 U20 |
Output Rack 1) U1 U2 U3 U4 DU4 U5 U6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 U16 U17 U18
Output Rack 2) U19 U20
Example: In-rack Duplicate with different Placement—Rack 1 has two groups of Unknowns for Duplicate placement: first Group U1..U10, second Group U11..U15. A Duplicate is created for the first Group. A Duplicate cannot be created for the second Group because although the Minimum is met, no room exists in the Rack for it, so it cannot be created
Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 U17 D17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
DUPLICATE |
DUP |
0 |
UNK ONLY |
10 |
5 |
END |
1 |
|
Y |
N |
LB |
|
U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU8U15; U16 U17 D17 U18 U19 U20 DU19 |
Output Rack 1) U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU8U15
Output Rack 2) U16 U17 D17 U18 U19 U20 DU19
Example: In-rack Replicate with different Placement
Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 U17 D17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
REPLICATE |
REP |
0 |
UNK AND DUP |
10 |
5 |
END |
1 |
|
Y |
N |
LB |
|
U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 RDU2 RU11; U15 U16 U17 D17 U18 U19 U20 DU19 |
Output Rack 1) U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 RDU2 RU11
Output Rack 2) U15 U16 U17 D17 U18 U19 U20 DU19
Example: In-rack Replicate with fixed Selection, but Sample does not exist at nominated place
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
REPLICATE |
REP |
3 |
UNK AND DUP |
10 |
1 |
IMMEDIATELY AFTER |
1 |
|
Y |
N |
LB |
|
U1 U2 U3 RU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 RU13 U14 U15 U16 U17 U18; U19 U20 |
Output Rack 1) U1 U2 U3 RU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 RU13 U14 U15 U16 U17 U18
Output Rack 2) U19 U20
Example: In-rack Replicate with fixed Selection
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
REPLICATE |
REP |
3 |
UNK AND DUP |
10 |
1 |
IMMEDIATELY AFTER |
1 |
|
Y |
N |
LB |
|
U1 U2 U3 RU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 RU13 U14 U15 U16 U17 U18; U19 U20 U21 R21 |
Output Rack 1) U1 U2 U3 RU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 RU13 U14 U15 U16 U17 U18
Output Rack 2) U19 U20 U21 R21
Example: In-rack Replicate with limited Selection Type—Rack 1 has two Groups of Unknowns for Replicate placement: first Group U1..U10, second Group U11..U15. A Replicate is created for the first Group. A Replicate cannot be created for the second Group because although the Minimum is met, no room exists in the Rack for it, so it cannot be created
Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 U16 U17 D17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
REPLICATE |
REP |
0 |
UNK ONLY |
10 |
5 |
END |
1 |
|
Y |
N |
LB |
|
U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 RU3; U16 U17 D17 U18 U19 U20 RU19 |
Output Rack 1) U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 U15 RU3
Output Rack 2) U16 U17 D17 U18 U19 U20 RU19
Example: In-rack Replicate with different Minimum
Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14 U15 U16 U17 D17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
REPLICATE |
REP |
0 |
UNK ONLY |
10 |
5 |
IMMEDIATELY AFTER |
1 |
|
Y |
N |
LB |
|
U1 U2 DU2 U3 U4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14; U15 U16 RU16 U17 D17 U18 U19 U20 |
Output Rack 1) U1 U2 DU2 U3 U4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14
Output Rack 2) U15 U16 RU16 U17 D17 U18 U19 U20
Example: In-rack Replicate with different Number to Apply
Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14 U15 U16 U17 D17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
REPLICATE |
REP |
0 |
UNK ONLY |
10 |
1 |
END |
2 |
|
Y |
N |
LB |
|
U1 U2 DU2 U3 U4 RU4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 RU12 RU12; U13 U14 DU14 U15 U16 RU16 RU16 U17 D17 U18 U19 U20 |
Output Rack 1) U1 U2 DU2 U3 U4 RU4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 RU12 RU12
Output Rack 2) U13 U14 DU14 U15 U16 RU16 RU16 U17 D17 U18 U19 U20
Example: In-rack Replicate with different Number to Apply and Minimum
Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14 DU14 U15 U16 U17 D17 U18 U19 U20
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
REPLICATE |
REP |
0 |
UNK ONLY |
10 |
5 |
END |
2 |
|
Y |
N |
LB |
|
U1 U2 DU2 U3 U4 RU4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14; DU14 U15 U16 RU16 RU16 U17 D17 U18 U19 U20 |
Output Rack 1) U1 U2 DU2 U3 U4 RU4 RU4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13 U14
Output Rack 2) DU14 U15 U16 RU16 RU16 U17 D17 U18 U19 U20
Example: In-rack Spike with different Selection Type
Input Sample Group is U1 DU1 U2 U3 U4 U5 U6 DU6 U7 U8 U9 U10 U11 DU11 U12 U13 U14 U15 DU15 U16 U17 U18 U19 U20 U21 U22 U23 U24 U25
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
SPIKE |
SPK |
0 |
UNK AND DUP |
10 |
1 |
IMMEDIATELY AFTER |
1 |
|
Y |
N |
LB |
|
U1 DU1 U2 U3 SU3 U4 U5 U6 DU6 U7 U8 U9 SU9 U10 U11 DU11 U12 U13 U14 U15; DU15 U16 U17 U18 SU18 U19 U20 U21 U22 U23 U24 U25 SU18 |
Output Rack 1) U1 DU1 U2 U3 SU3 U4 U5 U6 DU6 U7 U8 U9 SU9 U10 U11 DU11 U12 U13 U14 U15
Output Rack 2) DU15 U16 U17 U18 SU18 U19 U20 U21 U22 U23 U24 U25 SU18
Example: In-rack Replicate and In-rack Blank
Input Sample Group is U1 U2 DU2 U3 U4 DU4 U5 DU5 U6 U7 U8 U9 DU9 U10 U11 U12 U13
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
REPLICATE |
REP |
0 |
UNK AND DUP |
10 |
5 |
IMMEDIATELY AFTER |
1 |
|
Y |
|
|
|
U1 U2 DU2 U3 U4 RU4 DU4 U5 DU5 RDU5 U6 U7 U8 RU8 U9 DU9 U10 U11 U12 U13 |
|
In=rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 LB DU2 U3 U4 RU4 DU4 U5 DU5 RDU5 U6 LB U7 U8 RU8 U9 DU9 U10 U11; U12 U13 LB |
Output Rack 1) U1 U2 BLK DU2 U3 U4 RU4 DU4 U5 DU5 RDU5 U6 BLK U7 U8 RU8 U9 DU9 U10 U11
Output Rack 2) U12 U13 BLK
Example: Cross-rack Duplicate and In-rack Blank
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20
Rack size t
20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Cross-rack |
DUPLICATE |
DUP |
0 |
UNK ONLY |
10 |
5 |
IMMEDIATELY AFTER |
1 |
|
Y |
|
|
|
U1 U2 U3 U4 U5 DU5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 DU18 U19 U20 |
|
In-rack |
BLANK |
BLK |
3 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 LB U3 U4 U5 DU5 U6 U7 U8 U9 U10 LB U11 U12 U13 U14 U15 U16 U17; U18 DU18 LB U19 U20 |
Output Rack 1) U1 U2 LB U3 U4 U5 DU5 U6 U7 U8 U9 U10 LB U11 U12 U13 U14 U15 U16 U17
Output Rack 2) U18 DU18 LB U19 U20
Example: Cross-rack Duplicate and In-rack Blank with different Selection and Block size
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21 U22 U23 U24
Rack size is 20
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Cross-rack |
DUPLICATE |
DUP |
0 |
UNK ONLY |
10 |
5 |
IMMEDIATELY AFTER |
1 |
|
Y |
|
|
|
U1 U2 U3 DU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 DU15 U16 U17 U18 U19 U20 U21 DU21 U22 U23 U24 |
|
In-rack |
BLANK |
BLK |
19 |
|
20 |
1 |
|
2 |
|
Y |
N |
LB |
|
U1 U2 U3 DU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 DU15 U16 LB LB; U17 U18 U19 U20 U21 DU21 U22 U23 U24 LB LB |
Output Rack 1) U1 U2 U3 DU3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 DU15 U16 LB LB
Output Rack 2) U17 U18 U19 U20 U21 DU21 U22 U23 U24 LB LB
Example: In-rack Blank and In-rack Replicate—The Replicate placement is processed first
Input Sample Group is U1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21 U22 U23 U24
Rack size is 10
|
Stream Type |
Analytical Type |
QC Type Code |
Selection |
Selection Type |
Per Block |
Minimum |
Placement |
Number to Apply |
Secondary QC Type Code |
Propagate |
Use Group |
Standard Code |
Standard Group Code |
output Sample Stream |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
In-rack |
BLANK |
BLK |
10 |
|
10 |
1 |
|
1 |
|
Y |
N |
LB |
|
U1 U2 U3 U4 U5 U6 RU6 U7 U8 LB U9 U10 U11 RU11 U12 U13 U14 U15 U16 LB; U17 U18 U19 U20 U21 U22 U23 U24 LB |
|
In-rack |
REPLICATE |
REP |
0 |
UNK ONLY |
10 |
5 |
IMMEDIATELY AFTER |
1 |
|
Y |
|
|
|
U1 U2 U3 U4 U5 U6 RU6 U7 U8 U9 U10 U11 RU11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21 U22 U23 U24 |
Output Rack 1) U1 U2 U3 U4 U5 U6 RU6 U7 U8 LB U9 U10 U11 RU11 U12 U13 U14 U15 U16 LB
Output Rack 2) U17 U18 U19 U20 U21 U22 U23 U24 LB