QCSAMPLE_REPORTABLE
STRING, comprising a comma-separated list of analytical types of REP, BLK, STD or SPK
When batch QC samples are added to a report request for a production job, for each laboratory batch job associated with a sample scheme analyte in the report request:
- If not empty, then samples with a Primary Analytical Type of Replicate, Blank, Standard and/or Spike are brought into the report request.
- If empty (default on deploy), then all types of QC samples are brought in to the report request.
Typically the preference is not set at role or user level.