Program Settings - SAMANA
SAMANA program settings set the environment for the On-line application.
Setting Name | Description | Setting Value | Default |
---|---|---|---|
AccessLevel | The access level for each staff member to the On-line application. | n
| |
AddFirstSample | If enabled, then a default sample is added to the list at the start of the session. | Enabled | Disabled | |
AllowAutoOverwriteFormula | Where an analyte has a formula, when a result is received from an instrument:
| Enabled | Disabled | Disabled |
AllowProperties | If enabled, then the user can select the Properties option from the main browser to set or change the filter used to display records in the list-view panel. | Enabled | Disabled | |
AllowSampleNavigation | |||
AnalyteLockedStatuses | The comma-delimited list of analyte locked statuses. If a cell has a status which is in the list of AnalyteLockedStatuses, it is locked to non-level 3 users. | CPL | IGN | NVL | NA | IS | LNR | OWH | OWL | OFT | OFL | OFT, or a comma-delimited list of these analyte statuses. | CPL,IGN,NVL,NA,IS,LNR,QWH,QWL,QFH,QFL,QFT |
AutoRun1.. | The scripts that are run automatically when the On-lne application starts up. This allows for the automatic opening of multiple data capture sessions. | {VBScriptFile}.VBS | |
AutoStatusUpdate | Made obsolete in CCLAS 2.44.0. Previously: If enabled, then the job status for those samples which have been analysed is updated at the end of the On-line session. | Enabled | Disabled | |
Criteria1.. | The list of criteria used to select records for the jobs list. Each criterion is defined by a name and a SQL clause used to filter the records. Only one criteria can be active at a time. These criteria and the default criteria to be used can be changed by the user in the application as well as via the Staff application. If modified by the application, if program settings were only present for CCLASMGR, then they are copied into the individual user’s program settings. | {CriteriaName},{SQLStatement} | |
CurrentCriteria | The number of the current criterion. | n | |
DataCaptureErrorLog | The name of the log file for data capture events. | {FileName} | |
DetLimFailureColour | The colour used to display a cell where there are results that fall below the determination limit. | {Colour} | &H00C0FFFF (Red) |
FindNextUnanalysedQC | When needing to find the next QC sample in the job that does not have a result as yet:
This is useful where there is a chance that the combination of sample type and sample ident is not unique for a scheme in a job. | Enabled | Disabled | Disabled |
FormulaBackgroundColour | The background colour used when displaying a formula cell. | {Colour} | |
GridComboMaxItems | When selecting a job from the run list, then the number of jobs that appear in the drop-down list is limited by this number. | n | |
GridMaxItems | When selecting a scheme, CUID, sample type, sample ident or product from the run list, then the number of schemes, CUIDs, sample types, sample idents and products that appear in the drop-down list is limited by this number. | n | |
InitialRecords | The number of records to initially load onto the main sample list. | n | |
Instrument1.. | If defined, when selecting an instrument for a data capture session, then the instruments are defined by the list. The Filename is the IFF for the instrument communication. If not defined, then all instruments that have IFF files in the IFFScripts folder appear in the drop-down list. | {InstrumentName}, {FileName} | |
MainListViewColumn1.. | The columns of details displayed in the browse frame of this application. | {FieldName},Width,{ColumnHeading}[,{Picture}] | |
QCFailureColour | The background colour used when displaying a cell containing a QC sample that has failed the action limits. | {Colour} | |
QCWarningColour | The background colour used when displaying a cell containing a QC sample that has failed the warning limit. | {Colour} | |
RecalculateFormulae | If enabled, after sample data has been saved for a scheme, then formulae in schemes that are not loaded for the current session are evaluated for that sample. | Enabled | Disabled | |
SamanaRun1.. | The screens that are available from the Add menu option. This is typically used to select instruments or scan samples into run lists. Examples: SamAnaRun1=%ConfigDirectory%SamanaUDF1.SCR SAMANARun2=%ConfigDirectory%SamanaUDF2.SCR | {VBScriptFile}.SCR | |
SelectedRowColour | Default = 256 | ||
ShowTipOfTheDay | If enabled, then the content of the TipOfTheDayFile displays on application on start up. If disabled, then no tip of the day displays. | Enabled | Disabled | |
SpawnInvertedxMDE | If enabled, then the On-line application spawns the Data Entry inverted spreadsheet functionality in the background to enable the inter-scheme calculations to be performed, since the On-line application functionality only allows for intra-schemes calculations. | Enabled | Disabled | |
SupportOldFormulaNames | The user-defined form is available at the bottom of the SAMANA edit window, Example: SamanaUser.SCR | {VBScriptFile}.SCR | |
TipOfTheDayFile | The name of the file containing the current tip of the day for the application. Example: %CCLASRootDirectory%Tip\Samana.TIP | {FileName} | |
UseShortname | If enabled, then the short name of the analyte appears on sample results display. | Enabled | Disabled | |
UserForm | |||
Window | The position and size of the application window, in pixels. | Top,Left,Width,Height |