Change the dewatered status of holes
To flag holes as dewatered:
- Select the Measure module.
- Select a drill pattern in the DataBlast Items Tree.
The drill pattern displays in the Viewport.
- Select or filter holes as required. See Select objects in the viewport and Filter displayed holes.
- On the Hole Status ribbon menu, click Flag as Dewatered.
The Action Date/Time screen displays.
- Select the Action Date/Time from:
- Start of Current Shift (default): For shift configuration, see Maintain shifts.
- Current Date/Time
- Custom Date/Time: Update the Date and Time as required.
- Click OK.
The Water property is changed to 0 in the Hole properties.
- Click Save Changes.
To flag holes as not dewatered:
- Select the Measure module.
- Select a drill pattern in the DataBlast Items Tree.
The drill pattern displays in the Viewport.
- Select or filter holes as required.
- On the Hole Status ribbon menu, click Remove Dewatered Flag.
A confirmation message displays.
- Click Yes.
The Water property is returned to its previous value.
- Click Save Changes.
