Configure Modular drill integration
Activity steps:
- On the DataBlast application menu, select Site Maintenance.
The Site Maintenance screen displays.
- Select the Service Control node.
- Select the Drill Machine Import > Modular tab.
- Click Create Modular ProVision Control Record.
- Leave Modular ProVision Drill Machine Import Active unchecked while configuring the interface.
- Complete the following fields that are specific to Modular ProVision drill integration as required.
- Last Event ID Imported: The numerical event ID in the source Modular ProVision database from which to start looking for further records.
- Modular ProVision Database Connection String: Click the ellipsis (...) to open the Select Database Server and Database screen to enter connection details.
- Modular ProVision Database Timeout: The amount of wait time (in seconds) before terminating an attempt to query the Modular ProVision database and generating an error.
- Complete the following fields that are common to all drill interfaces as required.
- Create Fault on 0 or Null Diameter: If checked, when the diameter provided is 0 or if no diameter is provided, a drill fault record instead of a drill machine hole detail record.
- Reimport Skip Mode: If checked, processing of the current drill record is skipped if the hole already contains an undeleted drill machine record.
- Time Zone: Select the time zone of the source data.
- X/Y Deviation Diameter Count: The maximum number of design diameters distance in the X/Y plane from the design collar to the drilled collar that allows a hole to be considered within range. If the distance exceeds the amount represented by this value, the drill record is created as a drill fault, which requires manual confirmation as a valid hole record.
- Sleep after Processing: The number of minutes to suspend processing when there are no new records available for processing.
- Length Percentage Deviation: The percentage difference from the design drill length allowed before a hole is considered to require manual confirmation as a valid hole record.
- Thread Database Timeout: If cleared, resets to Server default.
- Angle Tolerance: The number of degrees difference from the design angle before a hole is considered to require manual confirmation as a valid hole record.
- Bearing Tolerance: The number of degrees difference from the design bearing before a hole is considered to require manual confirmation as a valid hole record.
- Ignore Drill Diameter: If checked, any drill diameter information provided by the source record is ignored.
- Coordinate Conversion to Unit Multiplier: A multiplier applied directly to any X, Y or RL coordinate values before use.
- Diameter Tolerance: The maximum percentage difference between the design and drill diameter before a hole is considered to require manual confirmation as a valid hole record.
- Apply Diameter Tolerance to Valid Diameters
- Drill Diameter Multiplier: A multiplier applied directly to the drill diameter value provided by the source drill import record.
- Drill Diameter Rounding: The number of decimal places to round the diameter values before use (applied after the Drill Diameter Multiplier).
- To enable the interface, check Modular Drill Machine Import Active.
- Click Save Changes.