Configure Flanders Drill Integration
Activity Steps
- On the DataBlast Application Menu, select Site Maintenance.
The Site Maintenance screen displays.
- Select the Service Control node.
- Select the Drill Machine Import » Flanders tab.
- Click Create Flanders Control Record.
- Leave Flanders Drill Machine Import Active unchecked while configuring the interface.
- Complete the following fields that are specific to Flanders drill integration as required.
- Last Date Imported—The date from which to start looking for further records.
- Flanders Database Connection String—Click the ellipsis (...) to open the Select Database Server and Database screen to enter connection details. Click Advanced for further connection details if required.
- Flanders Database Timeout—The amount of wait time (in seconds) before terminating an attempt to query the Flanders database and generating an error.
- Store Additional Data as Setout—Whether to use the mast heading and drill heading to store setout fields. If unchecked, no data is stored for the setout fields. Default: Checked.
- Attempt Recovery on Stuck Record—Whether a record is saved to the DataBlast Service fault log instead of having the Flanders importer stop unexpectedly if the import has failed for an unspecified reason when trying to save a drill entry. Only change this setting if advised to do so by Datamine Support. Default: Unchecked.
- Export File Extension—The file extension used for the drill pattern export file from DataBlast Pro. Select from TXT and CSV.
Note: The Export File Settings are read-only and are configured via the Flanders ARDVARC Blast Plan File Import Specification screen.
- Complete the following fields that are common to all drill interfaces as required.
- Create Fault on 0 or Null Diameter—If checked, when the diameter provided is 0 or if no diameter is provided, a drill fault record instead of a drill machine hole detail record.
- Reimport Skip Mode—If checked, processing of the current drill record is skipped if the hole already contains an undeleted drill machine record.
- Time Zone—Select the time zone of the source data.
- Sleep after Processing—The number of minutes to suspend processing when there are no new records available for processing.
- Thread Database Timeout—If cleared, resets to Server default.
- X/Y Deviation Diameter Count—The maximum number of design diameters distance in the X/Y plane from the design collar to the drilled collar that allows a hole to be considered within range. If the distance exceeds the amount represented by this value, the drill record is created as a drill fault, which requires manual confirmation as a valid hole record.
- Length Percentage Deviation—The percentage difference from the design drill length allowed before a hole is considered to require manual confirmation as a valid hole record.
- Angle Tolerance—The number of degrees difference from the design angle before a hole is considered to require manual confirmation as a valid hole record.
- Bearing Tolerance—The number of degrees difference from the design bearing before a hole is considered to require manual confirmation as a valid hole record.
- Coordinate Conversion to Unit Multiplier—A multiplier applied directly to any X, Y or RL coordinate values before use.
- Ignore Drill Diameter—If checked, any drill diameter information provided by the source record is ignored.
- Diameter Tolerance—The maximum percentage difference between the design and drill diameter before a hole is considered to require manual confirmation as a valid hole record.
- Apply Diameter Tolerance to Valid Diameters
- Drill Diameter Multiplier—A multiplier applied directly to the drill diameter value provided by the source drill import record.
- Drill Diameter Rounding—The number of decimal places to round the diameter values before use (applied after the Drill Diameter Multiplier).
- To enable the interface, check Flanders Drill Machine Import Active.
- Click Save Changes.