Configure WencoMine Drill Integration
Activity Steps
- On the DataBlast Application Menu, select Site Maintenance.
The Site Maintenance screen displays.
- Select the Service Control node.
- Select the Drill Machine Import » WencoMine tab.
- Click Create WencoMine Control Record.
- Leave WencoMine Drill Machine Import Active unchecked while configuring the interface.
- Complete the following fields that are specific to WencoMine drill integration as required.
- Last Timestamp Imported—The SQL Server timestamp in the DATABASE_ROW_VERSION column of the DRILL_TRANS table in the WencoMine database from which to start looking for further records. For a new mine site, set this timestamp to 0.
- WencoMine Drill Database Connection String—Click the ellipsis (...) to open the Select Database Server and Database screen to enter connection details. Click Advanced for further connection details if required.
- WencoMine Drill Database Timeout—The amount of wait time (in seconds) before terminating an attempt to query the WencoMine database and generating an error.
- Drill Navigation Export Format—The format used by the drill navigation export feature when outputting a file to be used by the WencoMine drill. If not specified, the default value of “%-,%s,%i,%1,%2,%c" is used. Except for the following replaceable tokens, values are used verbatim.
- %-—The drill pattern name
- %s—The hole identifier
- %i—A counter
- %1—The design collar coordinates
- %2—The design drill toe coordinates
- %c—The drill icon type/colour (currently only supports a value of 7)
- WencoMine Drill Template—Customise the WencoMine .cfg file export format to suit your site's drill setup. Example:Copy
EXACTATRAK
JOBFILE
1
TASKS
1
JOBDESC
{JOB_DESCRIPTION}
TASK
1
FILE
{PATTERN_NAME}.dxf
TASKDESC
{PATTERN_NAME}
DRILLHOLES
{PATTERN_NAME}.csv
{GPS_REFERENCES_LIST} - Ignore Records with Drill Depth Less Than—Minimum drill depth.
- Complete the following fields that are common to all drill interfaces as required.
- Create Fault on 0 or Null Diameter—If checked, when the diameter provided is 0 or if no diameter is provided, a drill fault record instead of a drill machine hole detail record.
- Reimport Skip Mode—If checked, processing of the current drill record is skipped if the hole already contains an undeleted drill machine record.
- Time Zone—Select the time zone of the source data.
- X/Y Deviation Diameter Count—The maximum number of design diameters distance in the X/Y plane from the design collar to the drilled collar that allows a hole to be considered within range. If the distance exceeds the amount represented by this value, the drill record is created as a drill fault, which requires manual confirmation as a valid hole record.
- Sleep after Processing—The number of minutes to suspend processing when there are no new records available for processing.
- Length Percentage Deviation—The percentage difference from the design drill length allowed before a hole is considered to require manual confirmation as a valid hole record.
- Thread Database Timeout—If cleared, resets to Server default.
- Angle Tolerance—The number of degrees difference from the design angle before a hole is considered to require manual confirmation as a valid hole record.
- Bearing Tolerance—The number of degrees difference from the design bearing before a hole is considered to require manual confirmation as a valid hole record.
- Ignore Drill Diameter—If checked, any drill diameter information provided by the source record is ignored.
- Coordinate Conversion to Unit Multiplier—A multiplier applied directly to any X, Y or RL coordinate values before use.
- Diameter Tolerance—The maximum percentage difference between the design and drill diameter before a hole is considered to require manual confirmation as a valid hole record.
- Apply Diameter Tolerance to Valid Diameters
- Drill Diameter Multiplier—A multiplier applied directly to the drill diameter value provided by the source drill import record.
- Drill Diameter Rounding—The number of decimal places to round the diameter values before use (applied after the Drill Diameter Multiplier).
- To enable the interface, check WencoMine Drill Machine Import Active.
- Click Save Changes.