REGMOW Process
To access this command:
- View the Find Command screen, select REGMOW and click Run.
- Enter "REGMOW" into the Command Line and press <ENTER>.
See this process in the Command Table.
Process Overview
Create a regular cell model for pit optimization.
Note: This can be performed on any type of Datamine block model.
Input Files
Name |
Description |
I/O Status |
Required |
Type |
IN1 |
Input model prototype file, defining the new model origin, number of cells and cell sizes. This is typically set up by process PROTOM. The fields required are XMORIG, YMORIG, ZMORIG, NX, NY, NZ, XINC, YINC, ZINC (all implicit) and IJK, XC, YC, and ZC (all explicit). |
Input |
Yes |
Block Model Prototype |
IN2 |
Input model file for conversion. This must have the fields XMORIG, YMORIG, ZMORIG, NX, NY, NZ (implicit) and IJK, XC, YC and ZC (explicit). XINC, YINC and ZINC must exist as either explicit (sub-cells permitted) or implicit (no sub-cells). There must also be at least one explicit numeric data field, to be specified as F1. The records may be in any order, but speed is greatly increased if they are in IJK order. |
Input |
Yes |
Block Model |
Output Files
Name |
I/O Status |
Required |
Type |
Description |
OUT |
Output |
Yes |
Block Model File |
Output model file. This will have the model parameters of the input prototype file on IN1 , and may contain up to five averaged fields ( F1-F5). It will also contain the fields OREVOL, WASVOL and AIRVOL. |
Fields
Name |
Description |
Source |
Required |
Type |
Default |
BLTYPE |
Field in IN2 which contains a specific value AIRVAL when the sub-cell is air. |
IN2 |
No |
Any |
Undefined |
F1-F5 |
Explicit numeric fields to be averaged. F1 is mandatory. |
IN2 |
Yes for F1, no otherwise. |
Numeric |
Undefined |
Parameters
Name |
Description |
Required |
Default |
Range |
Values |
AIRVAL |
The value of the BLTYPE field that will be used to recognize air blocks and sub-blocks in the input model. |
No |
Undefined |
Undefined |
Undefined |
CUTOFF1 |
If the value in field F1 is below this, the sub-cell is treated as waste. |
No |
Undefined |
Undefined |
Undefined |
RESTRICT |
Set to 1 if only the blocks on the input model are to be reported in the regularized model. Default is 0. |
No |
0 |
0,1 |
0,1 |
|
>=2 display for each input cell or sub-cell that intersects with an output model cell; IJK1, IJK, NUMMET, XC, YC, ZC, VOLP, VOLT, F1 [IJK of input and output cell, sub-cell no., input cell centre, volume intersected, total volume to date in output cell, F1 value] and for each output cell, IJK, WASVOL, OREVOL, the F1 name and the F1 value. (0). |
No |
0 |
0,2 |
0,1,2 |