Introduction

Copies records of a file which have X, Y and Z co-ordinates lying above/ below a wireframe surface or inside/outside a wireframe volume.

How to use

Surfaces and wireframes should not both be present in the triangles file unless individual models are specified for selection by setting a ZONE parameter. In-place operations are not permitted.


Files, Fields and Parameters

Input Files

Name

Description

I/O Status

Required

Type

IN

Input point file for selection. Must have explicit numeric fields X , Y and Z. Processing will be quicker if this file is sorted on X.

Input

Yes

Undefined

WIRETR

Input wireframe triangle file

Input

Yes

Wireframe Triangle

WIREPT

Input wireframe point file

Input

Yes

Wireframe Points

Output Files

Name

I/O Status

Required

Type

Description

OUT

Output

Yes

Undefined

Output file of selected records. File may contain additional fields, including the ZONE field.

Fields

Name

Description

Source

Required

Type

Default

X

Field in IN file defining the X co-ordinate.

IN

Yes

Numeric

Undefined

Y

Field in IN file defining the Y co-ordinate.

IN

Yes

Numeric

Undefined

Z

Field in IN file defining the Z co-ordinate.

IN

Yes

Numeric

Undefined

ZONE

Field in WIRETR file used to identify individual surfaces and solid models. If there is more than one surface or solid model and ZONE is not specified, a point may be selected more than once, one for each model. If this field is specified and ZONE is not, the ZONE field is copied to the output file.

WIRETR

No

Any

Undefined

ATTRIB1

Field from the WIRETR file to be placed into the output file for all records which are selected. Up to 4 words may be entered, which may be 4 numeric fields or a mixture of alphanumeric and numeric fields totalling 4 words.

WIRETR

No

Any

Undefined

ATTRIB2

Second field from the WIRETR file to be placed into the output file for all records selected.

WIRETR

No

Any

Undefined

ATTRIB3

Third field from the WIRETR file to be placed into the output file for all records selected.

WIRETR

No

Any

Undefined

ATTRIB4

Fourth field from the WIRETR file to be placed into the output file for all records selected.

WIRETR

No

Any

Undefined

Parameters

Name

Description

Required

Default

Range

Values

ZONE

Used to select one of a number of surface or wireframe models. This parameter must be specified if WIRETR contains a mix of surface and solid models. The SELECT parameter will determine whether a model is treated as a surface or wireframe.

No

Undefined

Undefined

Undefined

SELECT

 

Option

Description

1

select points above a surface

2

select points below a surface

3

select points inside a solid

4

select points outside a solid.

Yes

3

1,4

1,2,3,4

TOLERANC

Tolerance for selection criteria. A positive tolerance will enhance point selection (0.001).

No

0.001

Undefined

Undefined


Notes

  • @SELECT = 1 OR 2
    There may be points that are neither above or below if they are outside the range of triangles.
     

  • @SELECT = 3
    A point may lie inside more than one wireframe model. If this is the case it will appear more than once in the output file.
     

  • @SELECT = 4
    An outside point will be outside all wireframe models. Attribute fields will not be copied in this case.


Example

!SELTRI

&IN(POINTS),&OUT(POUT),&WIREPT(PT),&WIRETR(TR),
*X(XP),*Y(YP),*Z(ZP),@SELECT=3

NUMBER OF TRIANGLES = 152

NUMBER OF POINTS TO SELECT = 159

>>>100 RECORDS READ : TIME 14:43:41 <<<
>>>112 RECORDS IN FILE POUT <<<


Error and Warning Messages

Message

Description

Solution

>>> TRIANGLE POINT FIELDS MISSING <<<

The &WIREPT file is missing the required fields.

Check that the &WIREPT file contains the standard wireframe points filed fields.

 

 

 

>>> TRIANGLE FIELDS MISSING <<<

The &WIRETR file is missing the required fields.

Check that the &WIRETR file contains the standard wireframe triangles file fields.

 

 

 

>>> POINT SELECT FIELDS MISSING <<<

The selected X, Y and Z coordinate fields are not present in the &IN file.

Check that the defined  *X, *Y, *Z coordinate fields exist in the &IN file.

 

 

 

>>> INVALID PARAMETERS - PROCESS ABORT <<<

 Value for @SELECT is <1 or >4.

Select an @SELECT value which of 1, 2, 3 or 4.

 

 

 

>>> TRIANGLES HAVE INVALID POINT IDENTIFIERS <<<

The points and triangles files are not consistent.

Check that the defined wireframe triangle and wireframe points files are consistent. This can be done by loading them into the Design window i.e. drag-and-drop the wireframe triangle file into the Design window. If they load without error, then they are valid wireframe triangles and points files pair.  

 

 

 

>>> MISSING TRIANGLE POINTS <<<

The points and triangles files are not consistent.

"