Register samples for a job
To access job samples:
- Open a registered job to display the PROFILE—JobEdit Form.
- Select the Samples tab.
To enter sample idents using automatic ident entry:
- Select the Samples » Sample idents sub-tab to display the content of the sample ident file/field.
- Click Auto Idents to display the PROFILE—AutoIdents Form.
- Select the CUID SYSTEM Number Sequence from the list of Unique number sequences to view the Format of the sample idents. The last number used for the sequence is updated to the next number in the sequence every time the sequence is accessed.
- Enter the Number of samples.
- Click
to add the required number of sample idents to the Sample idents grid. - Repeat steps 3—5 to add more sample idents using other CUID SYSTEM Number Sequences.
- Click OK to close the form and update the Sample idents grid on the Sample idents sub-tab.
- Click Save to save the sample idents for the job.
To enter sample idents using manual ident entry:
- Select the Samples » Sample idents sub-tab to display the content of the sample idents file/field.
- To specify sample idents one at a time, typically used to define a CUID SYSTEM Number Sequence as the sample ident for a template job which is then used to generate sample idents for a job created from the template job:
- Select Ident type as 1, and enter the sample ident string in the Template.
- To specify sample idents using a sequence that increments or decrements by 1, with a wildcard string positioning the numerical fill:
- Select Ident type as 2, enter the sample ident string containing one wildcard string in the Template, and enter the From and To.
- To specify sample idents using a sequence that increments or decrements by a given step, with a wildcard string positioning the numerical fill:
- Select Ident type as 3, enter the sample ident string containing one wildcard string in the Template, and enter the From, To and Step.
- To specify sample idents using two sequences that each increment or decrement by a given step, with two wildcard strings positioning the numerical fills, typically used to enter down hole from-to type depth specifications as part of the sample number:
- Select Ident type as 4, enter the sample ident string containing two wildcard strings in the Template, enter the From, To and Step for the first sequence, and enter the From, To and Step for the second sequence.
- To specify sample idents using two sequences in which the first sequence increments or decrements by a given step and the second sequence iterates around supplied text strings, with two wildcard strings positioning the numerical and string fills:
- Select Ident type as 5, enter the sample ident string containing numeric one wildcard string and one text wildcard string in the Template, enter the From, To and Step, and enter each text replacement string on its own line in the Block.
- Click
to add the manually entered sample idents to the Sample idents grid. - Repeat steps 1—5 to add more sample idents using manual ident entry.
- Click Save to save the sample idents for the job's samples.
To enter external sample idents using manual ident entry:
- Select the Samples » External idents sub-tab to display the content of the external sample idents file/field.
- To specify external sample idents one at a time:
- Select Ident type as 1, and enter the external sample ident string in the Template. Note that if no "#" or "&" wildcard characters are entered in the template, then the template is automatically treated as an Ident type 1 template (for example: Sample 1, red colour is treated as a single type 1 ident entry).
- To specify external sample idents using a sequence that increments or decrements by 1, with a wildcard string positioning the numerical fill:
- Select Ident type as 2, enter the external sample ident string containing one wildcard string in the Template, and enter the From and To.
- To specify external sample idents using a sequence that increments or decrements by a given step, with a wildcard string positioning the numerical fill:
- Select Ident type as 3, enter the external sample ident string containing one wildcard string in the Template, and enter the From, To and Step.
- To specify external sample idents using two sequences that each increment or decrement by a given step, with two wildcard strings positioning the numerical fills, typically used to enter down hole from-to type depth specifications as part of the sample number:
- Select Ident type as 4, enter the external sample ident string containing two wildcard strings in the Template, enter the From, To and Step for the first sequence, end enter the From, To and Step for the second sequence.
- To specify external sample idents using two sequences in which the first sequence increments or decrements by a given step and the second sequence iterates around supplied text strings, with two wildcard strings positioning the numerical and string fills.
- Select Ident type as 5, enter the external sample ident string containing numeric one wildcard string and one text wildcard string in the Template, enter the From, To and Step, and enter each text replacement string on its own line in the Block.
- To register the associated samples as duplicate (DUP) samples instead of unknown (UNK) samples, add the string DUP at the start of any of the items in the External sample idents grid.
- Click
to add the manually entered external sample idents to the External sample idents grid. - Repeat steps 1—5 to add more external sample idents using manual ident entry.
- Click Save to save the external sample idents for the job's samples.
To enter descriptions using manual ident entry:
- Select the Samples » Descriptions sub-tab to display the content of the descriptions file/field.To specify descriptions one at a time:
- Select Ident type as 1, and enter the description string in the Template. Note that if no "#" or "&" wildcard characters are entered in the template, then the template is automatically treated as an Ident type 1 template (for example: Sample 1, red colour is treated as a single type 1 ident entry).
- To specify descriptions using a sequence that increments or decrements by 1, with a wildcard string positioning the numerical fill:
- Select Ident type as 2, enter the description string containing one wildcard string in the Template, and enter the From and To.
- To specify descriptions using a sequence that increments or decrements by a given step, with a wildcard string positioning the numerical fill:
- Select Ident type as 3, enter the description string containing one wildcard string in the Template, and enter the From, To and Step.
- To specify descriptions using two sequences that each increment or decrement by a given step, with two wildcard strings positioning the numerical fills, typically used to enter down hole from-to type depth specifications as part of the sample number:
- Select Ident type as 4, enter the description string containing two wildcard strings in the Template, enter the From, To and Step for the first sequence, end enter the From, To and Step for the second sequence.
- To specify descriptions using two sequences in which the first sequence increments or decrements by a given step and the second sequence iterates around supplied text strings, with two wildcard strings positioning the numerical and string fills.
- Select Ident type as 5, enter the description string containing numeric one wildcard string and one text wildcard string in the Template, enter the From, To and Step, and enter each text replacement string on its own line in the Block.
- To register the associated samples as duplicate (DUP) samples instead of unknown (UNK) samples, add the string DUP at the start of any of the items in the Descriptions grid.
- Click
to add the manually entered descriptions to the Descriptions grid. - Repeat steps 1—5 to add more descriptions using manual ident entry.
- Click Save to save the descriptions for the job's samples.
To enter product codes using manual ident entry:
- Select the Samples » Product codes sub-tab to display the content of the product codes file/field.
- To specify product codes one at a time:
- Select Ident type as 1, and enter the product code string in the Template. Note that if no "#" or "&" wildcard characters are entered in the template, then the template is automatically treated as an Ident type 1 template (for example: Sample 1, red colour is treated as a single type 1 ident entry).
- To specify product codes using a sequence that increments or decrements by 1, with a wildcard string positioning the numerical fill:
- Select Ident type as 2, enter the product code string containing one wildcard string in the Template, and enter the From and To.
- To specify product codes using a sequence that increments or decrements by a given step, with a wildcard string positioning the numerical fill:
- Select Ident type as 3, enter the product code string containing one wildcard string in the Template, and enter the From, To and Step.
- To specify product codes using two sequences that each increment or decrement by a given step, with two wildcard strings positioning the numerical fills, typically used to enter down hole from-to type depth specifications as part of the sample number:
- Select Ident type as 4, enter the product code string containing two wildcard strings in the Template, enter the From, To and Step for the first sequence, end enter the From, To and Step for the second sequence.
- To specify product codes using two sequences in which the first sequence increments or decrements by a given step and the second sequence iterates around supplied text strings, with two wildcard strings positioning the numerical and string fills.
- Select Ident type as 5, enter the product code string containing numeric one wildcard string and one text wildcard string in the Template, enter the From, To and Step, and enter each text replacement string on its own line in the Block.
- To register the associated samples as duplicate (DUP) samples instead of unknown (UNK) samples, add the string DUP at the start of any of the items in the Product codes grid.
- Click
to add the manually entered product codes to the Descriptions grid. - Repeat steps 1—5 to add more product codes using manual ident entry.
- Click Save to save the product codes for the job's samples.
To create sample idents using a custom form:
- Where the screen file defined by the UserIdentsTab Program Settings - PROFILE is located in the folder defined by the ConfigDirectory Program Settings—GLOBALSETTINGS for CCLASMGR, then select the User Idents sub-tab to view the form contained within the screen file. This tab is hidden if no screen file can be loaded,
- Interact with the custom form, as required, to create sample idents.