Maintain Electronic Detonators
Note: Refer to the manufacturer's product specifications when adding or editing an electronic detonator.
Access electronic detonator maintenance:
- On the DataBlast Application Menu, select Product Maintenance.The Product Maintenance screen displays. 
- Select the Detonators - Electronic node.The Product Maintenance Ribbon Menu displays. 
To add an electronic detonator:
- On the Product Maintenance ribbon menu, click Add Electronic Detonators.The <Product> screen displays. 
- In the Product Details field group:- Select the Supplier from the defined suppliers. See Maintain Suppliers.
- Enter the Product Range Name. This is the supplier's name for the product. Maximum length: 16 characters.
- Enter the Unit NEQ—The net explosive quantity, which must be between 0 and 5 grams.
- Enter the Sleep Time.
- Select whether the product Has Lengths.
- Enter the Supplier Range Short Name and Supplier Type Short Name if required for BLASTPLAN export. Maximum length: 5 characters.
- Select the Electronic Detonator System from the defined systems. See Maintain Electronic Detonator Systems.
- Enter the Display Name. This is the name you use for the product at your mine site.
- Select the Hazard Class from 1.1B, 1.1D, 1.4S, 1.5D, 3 and 5.1.
 Note: The Product Range Name, Unit NEQ, Sleep Time, Electronic Detonator System and Display Name are required. 
- In the Appearance field group, for the white and dark backgrounds, update the following fields as required.- Product Colour
- Text Colour
 
- If Has Lengths is checked, in the Lengths table:- To add a length:- Click Add Length.
- Enter the Length.
- Enter the Site Name. This is the name you use for the product at your mine site and must be unique. Default: The combination of the Product Range Name and Length (which is the Product Name).
- Click Save.
 
- To edit a length, select the length and click Edit; or double-click the length.
- To deactivate a length, uncheck Active.
 
- To add a length:
- Click Save.
- Click Save Changes.
To edit an electronic detonator:
- Select the electronic detonator.
- On the Product Maintenance ribbon menu, click Edit Product; or double-click the product.
- Edit the product as required.
- Click Save Changes.
To deactivate an electronic detonator:
- Uncheck Active for the electronic detonator.The product displays with strike-through text. 
- Click Save Changes.