Map Analysis Objects for Centric Integration

Use this activity to map analysis objects between MineMarket and Centric. For information about analysis objects, see Centric Analytics Configuration.

Security Note: You need the Allow the user to maintain Centric Analytics integration security right in the Centric Analytics Integration user group security rights group for this activity.

  1. Open the Analytics Connection for the Centric integration.
  2. Select the connection for the Centric integration with MineMarket in the Connections table.
  3. To create analysis objects:
    1. Right-click in the Analysis Objects table and select Map Analysis Objects from the menu.

      The Analytics Mapping Editor screen displays.

      The Data Tables grid displays the following information for all available MineMarket objects:

      • Object Type
      • Object Name
      • Dimension—Whether the object is mapped as a dimension.
      • Fact—Whether the object is mapped as a fact.
      • Status—Synchronisation status between MineMarket and Centric.
    2. Select Dimension and/or Fact for an object. You can select checkboxes for multiple objects. Selected objects display the Sync Pending status and selected Dimension or Fact fields are highlighted in blue.
    3. Click Synchronise.

      A message displays when the synchronisation finishes. Objects that failed to synchronise display an Error status and error message and the affected fields are highlighted in red.

    4. Click OK.
    5. Click Close.

      The Analytics Mapping Editor screen closes.

      Mapped analysis objects display in the Analysis Objects table in alphabetical order by object name. Objects mapped as facts are prefixed with F_. Objects mapped as dimensions are prefixed with D_.

  4. To delete analysis objects:
    1. Right-click in the Analysis Objects table and select Map Analysis Objects from the menu.

      The Analytics Mapping Editor screen displays.

    2. Uncheck Dimension and/or Fact for one or multiple mapped objects.

      Note: A Dimension cannot be deleted if Fact is selected for the object.

    3. Click Synchronise.

      A message displays when the synchronisation finishes.

    4. Click OK.
    5. Click Close.

      The Analytics Mapping Editor screen closes.

  5. Click Save.