Enter As-Built Data for Holes
If holes were not charged as planned, you can edit the decks for each hole as required.
Activity Steps
- Select the Charge module.
- Select a charge pattern in the DataBlast Items Tree.
The pattern displays in the Viewport.
- Ensure that the pattern is the active pattern. See Make a Pattern Active.
- To limit the data entry to a subset of the holes in the charge pattern, select the holes. See Select Objects in the Viewport.
- On the Charge Loading Ribbon Menu, click Enter Hole As-Built Data.
The Hole As-Built Data Ribbon Menu displays.
The holes display as a list in the left panel. The planned deck layout of the selected hole in the list displays in the middle panel. The right panel is for as-built data entry.
- For each deck in each hole:
- Select the Operator from the defined operators. See Maintain Operators.
- Select the Equipment from the defined trucks. See Maintain Mobile Processing Units (MPUs) and Maintain Stemming Trucks.
- Update the Time if required.
- For a bulk explosive, packaged explosive, aggregate material or gas bag, select the required product from the list of defined products of that type. See Product Maintenance.
- Drag the Bulk, PE, Aggregate, Gas Bag, Air, Water or Drill Cuttings button to the hole layout diagram.
The Deck Dimensions screen displays.
- Enter dimensions for the deck as required for the deck type:
- Deck Length—Not applicable to bulk explosives.
- Loaded Amount—Only applicable to bulk and packaged explosives.
- Top of Deck—Measured from the top of the hole, which is considered to be at 0 m.
- Bottom of Deck—Measured from the top of the hole.
Note: For a bulk explosive, at least two dimensions are required. For a packaged explosive, at least two length dimensions are required. Remaining dimensions are calculated.
- Click OK.
- Select the deck in the hole layout diagram to view calculated values and update details if required.
- To delete a deck, select the deck in the hole layout diagram and press Delete (on your keyboard).
- Click Save Changes.
- On the Hole As-Built Data ribbon menu, click Return to Charge.